Mouse Models of Cone and Cone-Rod Dystrophy in the MICRON Literature

About the MICRON Research Literature

These research pages organize published studies using MICRON imaging systems by animal species and the disease or condition investigated.

All publication counts and figures reflect the complete indexed research collection.

Explore related studies through the MICRON Research Hubs or search the complete publication collection in the reSEARCH portal.

Understanding Cone and Cone-Rod Dystrophy

Cone dystrophy and cone-rod dystrophy are inherited dystrophies in which cone function is lost first, with rod involvement following in the cone-rod form.

Early symptoms typically include:

  • Reduced acuity
  • Impaired color discrimination
  • Photophobia

The loss of acuity and central visual function is especially tied to the human fovea, where cone density is highest.

Cone and Cone-Rod Dystrophy in Experimental Research

The mouse retina is rod-dominated and has no fovea or cone-rich central region, so a mouse model reproduces the cone-specific molecular lesion and the cone's vulnerability to it without the central anatomy that gives the human disease its presentation.

Cone function in a mouse is read from the photopic and flicker electroretinogram, from opsin-specific stimuli and from cone-specific histology, rather than from acuity at a point of fixation.

Mouse Models of Cone and Cone-Rod Dystrophy

The mouse carries most of this work.

Transgenic and knockout lines allow a pathway to be removed or overexpressed, and cost, availability, short generation time and a large body of background data reinforce the choice.

A genetic manipulation constrains rather than isolates a mechanism: developmental compensation and pleiotropy remain possible.

Published MICRON Research: Cone and Cone-Rod Dystrophy in Mice

This page lists 10 papers from the MICRON literature, published 2017 to 2025, that study cone dystrophy or cone-rod dystrophy in mice.

Of these publications:

  • 10 studies used mice as the primary cone dystrophy or cone-rod dystrophy disease model.

Scope of the literature collection: Publication counts reflect studies identified and indexed in the MICRON research corpus. This collection is not intended to represent an exhaustive review of all published cone dystrophy or cone-rod dystrophy research.

Which imaging and experimental techniques are used in these studies?

Which imaging and experimental techniques are used in these studies?
Technique Papers
Electroretinography 10
Optical Coherence Tomography 6
Fundus Fluorescein Angiography 4
Topical Ophthalmic Drug Delivery 4

Technique counts are paper-level co-occurrences and do not necessarily indicate that a technique was applied to the focal species or focal disease model.

Capabilities and Limitations of Imaging Techniques

A summary of what each imaging technique listed above can measure, the information it provides, and its limitations in research applications.

Electroretinography

Records the retina's electrical response to light, giving component-sensitive information about outer- and inner-retinal function. It measures function directly, which no structural method does. Full-field ERG sums across the whole retina, so a small lesion can leave the trace unchanged; focal and multifocal variants trade signal amplitude for spatial resolution.

Optical Coherence Tomography

Optical coherence tomography provides high-resolution, cross-sectional images of ocular tissues in the living eye, allowing researchers to visualize structures at different depths. OCT is particularly useful for measuring tissue thickness, identifying structural abnormalities, and assessing the location and extent of tissue changes.

As a non-invasive imaging technique, OCT enables repeated measurements in the same eye over time, supporting longitudinal studies of disease progression and treatment response. Although OCT provides detailed structural information, it does not directly measure cellular activity or visual function. Tissue that appears structurally normal may still have functional abnormalities, making OCT a valuable companion to functional assessments such as electroretinography (ERG).

Fundus Fluorescein Angiography

Fundus fluorescein angiography uses an injected fluorescent dye to visualize blood flow through the retinal and choroidal circulation. Sequential images show how vessels fill, identify areas of reduced or absent perfusion, and reveal dye leakage associated with vascular abnormalities.

This technique is particularly useful for evaluating vascular perfusion, blood-retinal barrier integrity, and abnormal vessel growth. Fluorescein angiography primarily shows dye distribution rather than the surrounding retinal tissue. It provides a two-dimensional (en face) view in which vessels at different depths may overlap. Cross-sectional and cellular structural details require other imaging methods, such as optical coherence tomography (OCT) or optical coherence tomography angiography (OCT-A). Vascular abnormalities that do not affect dye filling or produce leakage may also remain undetected.

Topical Ophthalmic Drug Delivery

A compound applied as drops to the ocular surface. It is non-invasive and repeatable, so it supports frequent dosing without a procedure for each dose. What the route has to establish depends on the target: for an ocular-surface target, residence time and penetration into the surface tissue are the main barriers; for an intraocular anterior-segment target, the compound must cross ocular-surface and corneal or conjunctival barriers and reach an intraocular concentration sufficient for the experiment; for a posterior-segment target, additional ocular barriers separate the surface from the target and posterior-segment exposure is harder to establish.

Which MICRON systems and add-ons appear?

Which MICRON systems and add-ons appear?
Instrument Papers
MICRON IV 6
Image-Guided OCT 4
MICRON III 4
Ganzfeld ERG System 1
Image-Guided Focal ERG 1
Image-Guided Laser 1

Which strains and genetic lines are used?

Which strains and genetic lines are used?
Strain Papers Reported as
C57BL/6J 3
129P2-Gucy2ecpfl9/Boc 1
B6 1
C57Bl/6/129V 1
C5BL/6J-Mitfmi/+ 1

What other conditions are recorded on the same papers?

What other conditions are recorded on the same papers?
Disease Papers
Retinal Degeneration (General) 9
Retinal Pigment Epithelium Dysfunction 4
Retinal Neovascularization (General) 2
Retinitis Pigmentosa (RP) 2
Age-Related Macular Degeneration (Dry/Atrophic) 1
Age-Related Macular Degeneration (General) 1
Anophthalmia / Microphthalmia 1
Bardet-Biedl Syndrome 1
Choroidal Neovascularization 1
Congenital Stationary Night Blindness 1
Leber Congenital Amaurosis (LCA) 1
Light-Induced Retinal Degeneration 1
Neuronal Ceroid Lipofuscinoses (Batten Disease) 1
Retinal Dysplasia 1
Usher Syndrome 1

Which MICRON configurations appear in this work?

Configurations recorded in these papers, and the techniques recorded alongside them.

Which MICRON configurations appear in this work?
MICRON configuration Papers Most frequent techniques recorded alongside
MICRON IV 6 Electroretinography (6), Fundus Fluorescein Angiography (3), Optical Coherence Tomography (2)
Image-Guided OCT 4 Electroretinography (4), Optical Coherence Tomography (4), Topical Ophthalmic Drug Delivery (1)
MICRON III 4 Electroretinography (4), Optical Coherence Tomography (4), Fundus Fluorescein Angiography (1)
Ganzfeld ERG System 1 Electroretinography (1), Optical Coherence Tomography (1), Topical Ophthalmic Drug Delivery (1)
Image-Guided Focal ERG 1 Electroretinography (1), Fundus Fluorescein Angiography (1), Topical Ophthalmic Drug Delivery (1)
Image-Guided Laser 1 Electroretinography (1), Fundus Fluorescein Angiography (1), Optical Coherence Tomography (1)

The papers

The papers
Year Title Journal Role of focal species MICRON products Links
2025 Phosphodiesterase 5 expression in photoreceptors rescues retinal degeneration induced by deregulation of membrane guanylyl cyclase. The Journal of Biological Chemistry Disease model Ganzfeld ERG System DOI · reSEARCH
2024 The Microphthalmia-Associated Transcription Factor (MITF) and Its Role in the Structure and Function of the Eye. Genes Disease model Image-Guided OCT, MICRON IV DOI · reSEARCH
2023 Integration of human stem cell-derived in vitro systems and mouse preclinical models identifies complex pathophysiologic mechanisms in retinal dystrophy. Frontiers in Cell and Developmental Biology Disease model Image-Guided Laser, MICRON III DOI · reSEARCH
2023 Progressive Cone-Rod Dystrophy and RPE Dysfunction in Mitfmi/+ Mice. Genes Disease model MICRON IV DOI · reSEARCH
2022 A mouse model of cone photoreceptor function loss (cpfl9) with degeneration due to a mutation in Gucy2e. Frontiers in Molecular Neuroscience Disease model Image-Guided OCT, MICRON III DOI · reSEARCH
2020 Yap haploinsufficiency leads to Müller cell dysfunction and late-onset cone dystrophy. Cell Death & Disease Disease model Image-Guided Focal ERG, MICRON IV DOI · reSEARCH
2020 Retbindin: A riboflavin Binding Protein, Is Critical for Photoreceptor Homeostasis and Survival in Models of Retinal Degeneration. International Journal of Molecular Sciences Disease model MICRON IV DOI · reSEARCH
2020 Elimination of a Retinal Riboflavin Binding Protein Exacerbates Degeneration in a Model of Cone-Rod Dystrophy. Investigative Ophthalmology & Visual Science Disease model MICRON IV DOI · reSEARCH
2020 Mouse Models of Inherited Retinal Degeneration with Photoreceptor Cell Loss. Cells Disease model Image-Guided OCT, MICRON III, MICRON IV DOI · reSEARCH
2017 Loss of Extracellular Signal-Regulated Kinase 1/2 in the Retinal Pigment Epithelium Leads to RPE65 Decrease and Retinal Degeneration. Molecular and Cellular Biology Disease model Image-Guided OCT, MICRON III DOI · reSEARCH

Browse all hubs at MICRON Research Hubs. The full corpus is searchable in the reSEARCH portal.

Last built 2026-11-10 from content tag hubs-content-2026-11-10 (ae06cfc); fact-sheet run sheets-20261110T111119Z. About these hubs Back to top